Thumbnail
Access Restriction
Open

Author Garcia, Marie-Paule ♦ Villoing, Daphnée ♦ McKay, Erin ♦ Ferrer, Ludovic ♦ Cremonesi, Marta ♦ Botta, Francesca ♦ Ferrari, Mahila ♦ Bardiès, Manuel
Source United States Department of Energy Office of Scientific and Technical Information
Content type Text
Language English
Subject Keyword APPLIED LIFE SCIENCES ♦ ABSORBED RADIATION DOSES ♦ BIOMEDICAL RADIOGRAPHY ♦ COMPUTER CODES ♦ COMPUTERIZED SIMULATION ♦ DOSIMETRY ♦ GAMMA CAMERAS ♦ ICRP ♦ IMAGES ♦ MONTE CARLO METHOD ♦ PATIENTS ♦ POSITRON COMPUTED TOMOGRAPHY ♦ RADIOPHARMACEUTICALS ♦ SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
Abstract Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.
ISSN 00942405
Educational Use Research
Learning Resource Type Article
Publisher Date 2015-12-15
Publisher Place United States
Journal Medical Physics
Volume Number 42
Issue Number 12


Open content in new tab

   Open content in new tab