Thumbnail
Access Restriction
Subscribed

Author Meidert, Agnes S. ♦ Huber, Wolfgang ♦ Hapfelmeier, Alexander ♦ Schöfthaler, Miriam ♦ Müller, Johannes N. ♦ Langwieser, Nicolas ♦ Wagner, Julia Y. ♦ Schmid, Roland M. ♦ Saugel, Bernd
Source World Health Organization (WHO)-Global Index Medicus
Content type Text
Publisher Elsevier
File Format HTM / HTML
Language English
Difficulty Level Medium
Subject Domain (in DDC) Natural sciences & mathematics ♦ Life sciences; biology ♦ Physiology & related subjects ♦ Natural history of organisms ♦ Technology ♦ Medicine & health ♦ Human anatomy, cytology, histology ♦ Human physiology ♦ Pharmacology and therapeutics ♦ Diseases ♦ Manufacture for specific uses ♦ Precision instruments & other devices
Subject Domain (in MeSH) Cardiovascular System ♦ Anatomy ♦ Eukaryota ♦ Organisms ♦ Pathological Conditions, Signs and Symptoms ♦ Diseases ♦ Diagnosis ♦ Therapeutics ♦ Investigative Techniques ♦ Analytical, Diagnostic and Therapeutic Techniques and Equipment ♦ Circulatory and Respiratory Physiological Phenomena ♦ Biological Sciences ♦ Persons ♦ Persons
Subject Keyword Discipline Critical Care ♦ Aorta ♦ Physiology ♦ Arterial Pressure ♦ Blood Pressure Determination ♦ Methods ♦ Critical Care ♦ Manometry ♦ Monitoring, Physiologic ♦ Multiple Organ Failure ♦ Physiopathology ♦ Radial Artery ♦ Aged ♦ Instrumentation ♦ Female ♦ Humans ♦ Male ♦ Middle Aged ♦ Comparative Study ♦ Journal Article ♦ Research Support, Non-u.s. Gov't
Abstract PURPOSE: We compared blood pressure (BP) measurements obtained using radial artery applanation tonometry with invasive BP measurements using a catheter placed in the abdominal aorta through the femoral artery in patients with multiple organ dysfunction syndrome (MODS). MATERIALS AND METHODS: In 23 intensive care unit patients with MODS, we simultaneously assessed BP values for 15 minutes per patient using radial artery applanation tonometry (T-Line TL-200 pro device; Tensys Medical Inc, San Diego, Calif) and the arterial catheter (standard-criterion technique). A total of 2879 averaged 10-beat epochs were compared using Bland-Altman plots. RESULTS: The mean difference ± SD (with corresponding 95% limits of agreement) between radial artery applanation tonometry-derived BP and invasively assessed BP was +1.0 ± 5.5 mm Hg (-9.9 to +11.8 mm Hg) for mean arterial pressure, -3.3 ± 11.2 mm Hg (-25.3 to +18.6 mm Hg) for systolic arterial pressure, and +4.9 ± 7.0 mm Hg (-8.8 to +18.6 mm Hg) for diastolic arterial pressure, respectively. CONCLUSIONS: In intensive care unit patients with MODS, mean arterial pressure and diastolic arterial pressure can be determined accurately and precisely using radial artery applanation tonometry compared with central aortic values obtained using a catheter placed in the abdominal aorta through the femoral artery. Although systolic arterial pressure could also be derived accurately, wider 95% limits of agreement suggest lower precision for determination of systolic arterial pressure.
Description Country affiliation: Germany
Author Affiliation: Meidert AS ( II. Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Strasse 22, 81675 München, Germany.)
ISSN 08839441
Educational Role Student ♦ Teacher
Age Range above 22 year
Educational Use Reading ♦ Research ♦ Self Learning
Interactivity Type Expositive
Education Level UG and PG
Learning Resource Type Article
Publisher Date 2013-12-01
Publisher Place United States
e-ISSN 15578615
Journal Journal of Critical Care
Volume Number 28
Issue Number 6