Thumbnail
Access Restriction
Open

Author Panjali, N. ♦ Sathiyanarayanan, S. ♦ Venkatachari, G. ♦ Ramakrishnan, K. R. ♦ Rengaswamy, N. S.
Source CSIR-Central Electrochemical Research Institute
Content type Text
Publisher Central Electrochemical Research Institute
File Format PDF
Copyright Year ©1999
Language English
Subject Domain (in DDC) Technology ♦ Engineering & allied operations
Subject Keyword Corrosion Science and Engineering ♦ Electrochemical Instrumentation
Abstract Due to rapid industrialisation the atmosphere is polluted by acidic gases like SOl' HzS, NOl etc, which increase the corrosivity of atmosphere. For continuous monitoring of the atmospheric corrosivity a prohe and coulometer have been designed. From tbe measured coulombs the corrosivity of atmospbere can he monitored. This paper presents the results of tbe performance of the monitor.
Educational Use Research
Education Level UG and PG
Learning Resource Type Article
Publisher Date 1999-01-01
Journal PeerReviewed