Thumbnail
Access Restriction
Open

Author Bartosik, H. ♦ Hofle, W.
Source CERN Document Server
Content type Text
File Format PDF
Date Created 2012-02-23
Language English
Subject Domain (in DDC) Natural sciences & mathematics ♦ Physics ♦ Modern physics ♦ Technology ♦ Engineering & allied operations ♦ Applied physics
Subject Keyword Accelerators and Storage Rings
Abstract An MD on August 26, 2011 was dedicated to injection studies of bunch trains with 25 ns spacing and nominal intensity of approximately 1×10(11) protons per bunch. Due to an electrical glitch, the MD was stopped after two attempts of injecting a train of 48 bunches for beam 2. Both injections were aborted after less than 0.1 s. In particular, the first attempt with transverse damper on was dumped after 1000 turns while the second attempt with transverse damper off was dumped after 500 turns only. In this note, an analysis of the bunch by bunch oscillation data recorded with the post-mortem system from the transverse damper is presented. The presented data clearly shows the presence of instabilities that affect mainly the second half of the batch. This is compatible with what would be expected qualitatively in the presence of the electron cloud effect.
Learning Resource Type Report
Publisher Date 2012-01-01
Organization CERN. Geneva. ATS Department