Author Young, Lori A. ♦ Sandison, George ♦ Yang, Fei ♦ Woodworth, Davis ♦ McCormick, Zephyr
Source United States Department of Energy Office of Scientific and Technical Information
Content type Text
Language English
Subject Keyword RADIOLOGY AND NUCLEAR MEDICINE ♦ RADIATION PROTECTION AND DOSIMETRY ♦ ACCURACY ♦ ALUMINIUM OXIDES ♦ CALIBRATION ♦ CALIBRATION STANDARDS ♦ COMMISSIONING ♦ CYCLOTRONS ♦ DOPED MATERIALS ♦ DOSEMETERS ♦ DOSIMETRY ♦ ELECTRON BEAMS ♦ FAST NEUTRONS ♦ IN VIVO ♦ IRRADIATION ♦ LUMINESCENCE ♦ MEV RANGE 10-100 ♦ NEUTRON BEAMS ♦ NEUTRON THERAPY ♦ PHANTOMS ♦ RADIATION DOSES
Abstract Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.
ISSN 00942405
Educational Use Research
Learning Resource Type Article
Publisher Date 2016-01-15
Publisher Place United States
Journal Medical Physics
Volume Number 43
Issue Number 1