Thumbnail
Access Restriction
Open

Author Ray, Sachet
Researcher Ray, Sachet
Advisor Gupta, Aditya Kumar
Source NIT Rourkela-Thesis
Content type Text
Educational Degree Bachelor of Technology (B.Tech.)
File Format PDF
Language English
Subject Domain (in DDC) Technology ♦ Engineering & allied operations ♦ Applied physics
Subject Keyword Power Systems
Abstract Most of the high voltage equipment suffers from failure due to internal faults. The type of fault caused due to insulation failure as a consequence of local electrical stress concentration in the insulation, whether gas, solid or liquid is very widely prevalent. This is called as partial discharge. So, partial discharge detection is highly important for an early detection of insulation failure. In this study, the simulation of partial discharge has been carried out with consideration of a cylindrical void inside an epoxy resin. The PD characteristic is studied by applying different high voltages across the insulation, which is necessary for designing of a calibration circuit. A calibration circuit has been modeled in SIMULINK for generation of PD pulses of known charge magnitude. The calibrator was connected across the test object and the pulses were detected via detector. A physical model of calibrator was made and output calibrating pulses were observed at Digital Storage Oscilloscope.
Education Level UG and PG
Learning Resource Type Thesis
Publisher Date 2013-01-01